Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Package / Case | Features | Approval Agency | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Fuse Type | Class | Breaking Capacity @ Rated Voltage | Melting I²t | DC Cold Resistance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
C10M1I | - | ![]() |
7807 | 0.00000000 | Eaton - Bussmann Electrical Division | C10M | Bulk | Obsolete | - | Motor Protection | 0.406" Dia x 1.500" L (10.30mm x 38.00mm) | Requires Holder | Cylindrical, Alarm Indicating, 5AG, 10x38.1mm | Indicating | - | download | RoHS Compliant | 1 (Unlimited) | EAR99 | 8536.10.0040 | 10 | 1A | 500 VAC | - | Cartridge | - | 120kA | ||||||
![]() |
170M1320 | 200.6300 | ![]() |
23 | 0.00000000 | Eaton - Bussmann Electrical Division | - | Bulk | Active | - | Electrical, Industrial | 2.126" L x 0.827" W x 1.575" H (54.00mm x 21.00mm x 40.00mm) | Bolt Mount | Rectangular, Blade | - | CE, UR | download | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 10 | 200A | 700 VAC | - | Square | - | 200kA | 4200 | |||||
![]() |
TC-20PK4 | 72.7000 | ![]() |
6762 | 0.00000000 | Eaton - Bussmann Electrical Division | * | Bulk | Active | - | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 1 | |||||||||||||||||||
![]() |
170M8621 | 847.4800 | ![]() |
6495 | 0.00000000 | Eaton - Bussmann Electrical Division | - | Bulk | Active | - | - | 3.189" L x 2.913" W x 3.622" H (80.00mm x 74.00mm x 92.00mm) | Bolt Mount | Rectangular, Blade | - | download | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 1 | 700A | 1 kVAC | - | Square | - | 115000 | |||||||
![]() |
5CLE-25E | 784.7100 | ![]() |
8251 | 0.00000000 | Eaton - Bussmann Electrical Division | HLE | Bulk | Active | - | Transformer Protection | 2.000" Dia x 12.900" L (50.80mm x 327.66mm) | Requires Holder | Cartridge, Non-Standard | - | UL | - | Not Applicable | EAR99 | 8535.10.0020 | 1 | 25A | 5.5 kVAC | - | Cartridge | - | 50kA | |||||||
NON-30 | 14.5000 | ![]() |
15 | 0.00000000 | Eaton - Bussmann Electrical Division | NON | Bulk | Active | - | Electrical, Industrial | 0.560" Dia x 2.000" L (14.22mm x 50.80mm) | Requires Holder | Cartridge, Non-Standard | - | CE, CSA, UL | download | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 10 | 30A | 250 VAC | 125 VDC | - | Cartridge | K5 | 50kA | ||||||
![]() |
STD4 | 20.7090 | ![]() |
9929 | 0.00000000 | Eaton - Bussmann Electrical Division | STD | Bulk | Active | - | Electrical, Industrial | 0.476" Dia x 0.945" L (12.10mm x 24.00mm) | Bolt Mount | Cylindrical, Blade Terminal (Bolt) | - | - | download | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 20 | 4A | 240 VAC | - | Cartridge | - | 33kA | 5.4 | |||||
![]() |
CDS70 | 108.9160 | ![]() |
5460 | 0.00000000 | Eaton - Bussmann Electrical Division | CDS | Bulk | Active | - | Electrical, Industrial | - | Requires Holder | Cartridge, Non-Standard | - | CE, CSA | download | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 5 | 70A | 600 VAC | Slow Blow | Cartridge | - | 10kA | ||||||
![]() |
FNA-1/4 | 65.7030 | ![]() |
5300 | 0.00000000 | Eaton - Bussmann Electrical Division | FNA | Bulk | Active | - | Electrical, Industrial | 0.406" Dia x 1.500" L (10.31mm x 38.10mm) | Requires Holder | Cylindrical, Alarm Indicating, 5AG, 10x38.1mm | Indicating | CE, CSA, UL | download | RoHS Compliant | Not Applicable | FNA-1-4 | EAR99 | 8536.10.0040 | 10 | 250mA | 250 VAC | Slow Blow | Cartridge | - | 35A | |||||
![]() |
8CLS-60 | 1.0000 | ![]() |
7802 | 0.00000000 | Eaton - Bussmann Electrical Division | CLS | Bulk | Active | - | Motor Protection | 3.000" Dia x 17.900" L (76.20mm x 454.66mm) | Requires Holder | Cartridge, Non-Standard | - | - | download | Not Applicable | EAR99 | 8535.10.0020 | 1 | 60A | 8.3 kVAC | - | Cartridge | - | 50kA | |||||||
![]() |
170M3966 | 497.1400 | ![]() |
3855 | 0.00000000 | Eaton - Bussmann Electrical Division | - | Bulk | Active | - | - | 3.150" L x 1.693" W x 2.402" H (80.00mm x 43.00mm x 61.00mm) | Bolt Mount | Rectangular, Blade | - | CE, UL | download | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 6 | 63A | 1 kVAC | - | Square | - | 215 | ||||||
![]() |
JKS-450 | 1.0000 | ![]() |
6887 | 0.00000000 | Eaton - Bussmann Electrical Division | Limitron™ JKS | Bulk | Active | - | Electrical, Industrial | 2.500" Dia x 3.750" L (63.50mm x 95.25mm) | Bolt Mount | Cylindrical, Blade Terminal (Bolt) | - | CE, CSA, UL | download | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 1 | 450A | 600 VAC | Fast Blow | Cartridge | J | 200kA | ||||||
![]() |
170M1408 | 165.7590 | ![]() |
1607 | 0.00000000 | Eaton - Bussmann Electrical Division | - | Bulk | Active | - | - | 2.126" L x 0.827" W x 1.575" H (54.00mm x 21.00mm x 40.00mm) | Bolt Mount | Rectangular, Blade | - | CE, CSA, UL | download | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 10 | 10A | 690 VAC | - | Square | - | 200kA | 3.8 | |||||
![]() |
S-3 | - | ![]() |
4027 | 0.00000000 | Eaton - Bussmann Electrical Division | * | Bulk | Obsolete | download | RoHS Compliant | 1 (Unlimited) | S-3EB | EAR99 | 8536.10.0040 | 4 | ||||||||||||||||||
![]() |
3.6WDFHO125 | 1.0000 | ![]() |
2184 | 0.00000000 | Eaton - Bussmann Electrical Division | - | Bulk | Active | - | - | 2.007" Dia x 10.000" L (51.00mm x 254.00mm) | Requires Holder | Cylindrical, Blade Terminal (Bolt) | - | - | download | RoHS Compliant | Not Applicable | 3-6WDFHO125 | EAR99 | 8535.10.0020 | 1 | 125A | 3.6 kVAC | - | Cartridge | - | 50kA | 13000 | 2.44 mOhms | |||
![]() |
2CLE-80E | 966.5100 | ![]() |
5073 | 0.00000000 | Eaton - Bussmann Electrical Division | CLE | Bulk | Active | - | Transformer Protection | 3.000" Dia x 10.900" L (76.20mm x 276.86mm) | Requires Holder | Cartridge, Non-Standard | - | UL | download | Not Applicable | EAR99 | 8535.10.0020 | 1 | 80A | 2.75 kVAC | - | Cartridge | - | 50kA | |||||||
![]() |
170L5714 | 660.9500 | ![]() |
6025 | 0.00000000 | Eaton - Bussmann Electrical Division | - | Bulk | Active | - | - | - | - | - | - | - | - | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 1 | 400A | 1 kVAC | - | - | - | - | ||||||
![]() |
PVS-R-90 | 195.7300 | ![]() |
4520 | 0.00000000 | Eaton - Bussmann Electrical Division | * | Bulk | Active | download | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 1 | |||||||||||||||||||
![]() |
KGX-A-15 | 219.2700 | ![]() |
5458 | 0.00000000 | Eaton - Bussmann Electrical Division | * | Bulk | Active | - | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 1 | |||||||||||||||||||
![]() |
KWS-R-40 | 177.8160 | ![]() |
6422 | 0.00000000 | Eaton - Bussmann Electrical Division | * | Bulk | Active | - | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 10 | |||||||||||||||||||
![]() |
35LET | 95.3970 | ![]() |
6593 | 0.00000000 | Eaton - Bussmann Electrical Division | LET | Bulk | Active | - | Electrical, Industrial | 0.697" Dia x 1.032" L (17.70mm x 26.20mm) | Bolt Mount | Cylindrical, Blade Terminal (Bolt) | - | CE, UR | download | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 10 | 35A | 240 VAC | 150 VDC | - | Cartridge | - | 200kA | 50 | ||||
![]() |
170M5474 | 1.0000 | ![]() |
3453 | 0.00000000 | Eaton - Bussmann Electrical Division | 170M | Bulk | Active | Rectangular, Blade | - | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 1 | Square | |||||||||||||||||
![]() |
KTK-R-2 | 45.1300 | ![]() |
10 | 0.00000000 | Eaton - Bussmann Electrical Division | Limitron™ KTK-R | Bulk | Active | - | Electrical, Industrial | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | Requires Holder | 5AG, 10mm x 38mm (Midget) | - | CE, CSA, UL | download | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 10 | 2A | 600 VAC | Fast Blow | Cartridge | CC | 200kA | ||||||
![]() |
170M4267 | 565.5800 | ![]() |
8972 | 0.00000000 | Eaton - Bussmann Electrical Division | - | Bulk | Active | - | Electrical, Industrial | 1.969" L x 2.087" W x 2.598" H (50.00mm x 53.00mm x 66.00mm) | Bolt Mount | Rectangular, Blade | Indicating | CE, CSA, UR | download | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 3 | 700A | 700 VAC | - | Square | - | 200kA | 69500 | |||||
![]() |
170M6516 | 841.5667 | ![]() |
9753 | 0.00000000 | Eaton - Bussmann Electrical Division | - | Bulk | Active | - | Electrical, Industrial | 2.008" L x 2.992" W x 3.622" H (51.00mm x 76.00mm x 92.00mm) | Requires Holder | Rectangular, Blade | Indicating | CSA, UR | download | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 3 | 1.25kA | 700 VAC | - | Square | - | 200kA | 290000 | |||||
![]() |
ECSR7 | 50.9590 | ![]() |
8785 | 0.00000000 | Eaton - Bussmann Electrical Division | ECSR | Bulk | Active | - | Electrical, Industrial | 0.810" Dia x 5.00" L (20.57mm x 127.00mm) | Requires Holder | Cartridge, Non-Standard | - | CE, CSA, UL | download | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 10 | 7A | 600 VAC | Slow Blow | Cartridge | RK5 | 200kA | ||||||
![]() |
170M1321 | 160.9900 | ![]() |
11 | 0.00000000 | Eaton - Bussmann Electrical Division | - | Bulk | Active | - | Electrical, Industrial | 2.126" L x 0.827" W x 1.575" H (54.00mm x 21.00mm x 40.00mm) | Bolt Mount | Rectangular, Blade | - | CE, CSA, UR | download | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 10 | 250A | 700 VAC | - | Square | - | 200kA | 4200 | |||||
![]() |
SPP-6M700 | - | ![]() |
8712 | 0.00000000 | Eaton - Bussmann Electrical Division | Semitron™ SPP | Bulk | Obsolete | - | - | Requires Holder | Fuse Link | - | 1 (Unlimited) | REACH Unaffected | EAR99 | 8536.10.0040 | 1 | - | ||||||||||||||
![]() |
170E3950 | 1.0000 | ![]() |
1447 | 0.00000000 | Eaton - Bussmann Electrical Division | - | Bulk | Active | - | - | 8.543" L x 2.244" W x 2.756" H (217.00mm x 57.00mm x 70.00mm) | Bolt Mount | Rectangular, Blade | - | - | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0040 | 1 | 20A | 2 kVDC | - | Square | - | 100kA | ||||||
![]() |
BBU27-40K | - | ![]() |
5778 | 0.00000000 | Eaton - Bussmann Electrical Division | - | Bulk | Active | - | Transformer Protection | - | In Line | Cartridge, Inline, Double Ended | Indicating | - | download | Not Applicable | 2041-BBU27-40K | 1 | 40A | 27 kVAC | Fast Blow | Cartridge | K | 12.5kA |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse