Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Package / Case Type Features Base Product Number Approval Agency Voltage - Input (Max) Supplier Device Package DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Control Features Current - Output (Max) Voltage - Input (Min) Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Isolation Standard Number
TEP 160-4818 Traco Power TEP 160-4818 218.0500
RFQ
ECAD 3 0.00000000 Traco Power TEP 160 (196W) Box Active -40°C ~ 75°C ITE (Commercial), Railway 2.40" L x 2.28" W x 0.50" H (61.0mm x 57.9mm x 12.7mm) Through Hole 9-DIP Module Isolated Module Remote On/Off, OTP, OVP, SCP TEP 160 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 192 W 1 4A 33V 92% 48V - - - 2.25 kV
TEN 3-1213N Traco Power TEN 3-1213N 14.3670
RFQ
ECAD 2290 0.00000000 Traco Power TEN 3N (3W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module SCP TEN 3 CB, cCSAus 18V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 3 W 1 200mA 9V 85% 15V - - - 1.5 kV
THM 3-2410 Traco Power THM 3-2410 42.0200
RFQ
ECAD 20 0.00000000 Traco Power THM 3 (3W) Tube Active -40°C ~ 90°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module OCP, OVP, SCP THM 3 36V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 3.3 W 1 1A 9V 82% 3.3V - - - 5 kV
TRN 3-1221SM Traco Power TRN 3-1221SM 25.0150
RFQ
ECAD 8261 0.00000000 Traco Power TRN 3SM (3W) Tube Active -40°C ~ 85°C ITE (Commercial) 0.47" L x 0.44" W x 0.31" H (11.9mm x 11.3mm x 8.0mm) Surface Mount 7-SMD Module Isolated Module SCP TRN 3 18V - download ROHS3 Compliant 2A (4 Weeks) REACH Unaffected EAR99 8504.40.9580 10 3 W 2 300mA, 300mA 9V 78% 5V -5V - - 1.6 kV
TMR 2-4812E Traco Power TMR 2-4812E 12.5240
RFQ
ECAD 2565 0.00000000 Traco Power TMR 2E (2W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.86" L x 0.37" W x 0.44" H (21.8mm x 9.3mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 2 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 2 W 1 167mA 36V 79% 12V - - - 1 kV
TEN 60-4822WIR Traco Power TEN 60-4822WIR 141.5600
RFQ
ECAD 15 0.00000000 Traco Power TEN 60WIR (60W) Box Active -40°C ~ 85°C (With Derating) ITE (Commercial), Railway 2.00" L x 1.60" W x 1.00" H (50.8mm x 40.7mm x 25.4mm) Through Hole 8-DIP Module Isolated Module Adjustable Output, Remote On/Off TEN 60 - 75V - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 1951-TEN60-4822WIR EAR99 8504.40.9580 10 60 W 2 - 2.5A, 2.5A 18V 92% 12V -12V - - 3 kV
TEN 40-4822N Traco Power TEN 40-4822N 78.0200
RFQ
ECAD 10 0.00000000 Traco Power TEN 40N (40W) Tube Active -40°C ~ 80°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OVP, SCP, UVLO TEN 40 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 40 W 2 1.67A, 1.67A 36V 89% 12V -12V - - 1.5 kV
TEP 100-4815 Traco Power TEP 100-4815 167.7500
RFQ
ECAD 1 0.00000000 Traco Power TEP 100 (100W) Box Active -40°C ~ 75°C ITE (Commercial), Railway 2.40" L x 2.28" W x 0.50" H (61.0mm x 57.9mm x 12.7mm) Through Hole 9-DIP Module Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO TEP 100 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 101 W 1 4.2A 36V 90% 24V - - - 2.25 kV
TBA 1-1223E Traco Power TBA 1-1223E 3.8800
RFQ
ECAD 36 0.00000000 Traco Power TBA 1E (1W) Tube Active -40°C ~ 95°C (With Derating) ITE (Commercial) 0.77" L x 0.24" W x 0.39" H (19.5mm x 6.0mm x 10.0mm) Through Hole 7-SIP Module, 5 Leads Isolated Module SCP TBA 1 - 13.2V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 990 mW 2 33mA, 33mA 10.8V 80% 15V -15V - - 1.5 kV
TEN 10-4811 Traco Power TEN 10-4811 51.8700
RFQ
ECAD 7 0.00000000 Traco Power TEN 10 (10W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module, 4 Leads Isolated Module OCP, OVP, SCP TEN 10 75V - download ROHS3 Compliant Not Applicable REACH Unaffected TEN10-4811 EAR99 8504.40.9580 10 10 W 1 2A 36V 80% 5V - - - 1.5 kV
THD 15-2423N Traco Power THD 15-2423N 55.7600
RFQ
ECAD 7117 0.00000000 Traco Power THD 15N (15W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 9 Leads Isolated Module Remote On/Off, OVP, SCP THD 15 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2263 EAR99 8504.40.9580 10 15 W 2 500mA, 500mA 18V 90% 15V -15V - - 1.5 kV
TDR 2-1212WISM Traco Power TDR 2-1212WISM 29.0020
RFQ
ECAD 6271 0.00000000 Traco Power TDR 2WISM (2W) Tube Active -40°C ~ 85°C ITE (Commercial) 0.74" L x 0.50" W x 0.34" H (18.9mm x 12.8mm x 8.7mm) Surface Mount 14-SMD Module, 7 Leads Isolated Module Remote On/Off, SCP TDR 2 18V - download ROHS3 Compliant 2A (4 Weeks) REACH Unaffected EAR99 8504.40.9580 10 2 W 1 167mA 4.5V 80% 12V - - - 1.6 kV
TEP 160-4815 Traco Power TEP 160-4815 220.1300
RFQ
ECAD 1 0.00000000 Traco Power TEP 160 (196W) Box Active -40°C ~ 75°C ITE (Commercial), Railway 2.40" L x 2.28" W x 0.50" H (61.0mm x 57.9mm x 12.7mm) Through Hole 9-DIP Module Isolated Module Remote On/Off, OTP, OVP, SCP TEP 160 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 192 W 1 8A 33V 92% 24V - - - 2.25 kV
TDN 1-4812WISM Traco Power TDN 1-4812WISM 19.4700
RFQ
ECAD 10 0.00000000 Traco Power TDN 1WISM (1W) Tube Active -40°C ~ 90°C ITE (Commercial) 0.52" L x 0.36" W x 0.40" H (13.2mm x 9.1mm x 10.2mm) Surface Mount 7-SMD Module, 6 Leads Isolated Module Remote On/Off, SCP TDN 1 75V - download ROHS3 Compliant 2 (1 Year) REACH Unaffected EAR99 8504.40.9580 10 1.1 W 1 90mA 18V 81% 12V - - - 1.6 kV
TEN 5-4823WI Traco Power TEN 5-4823WI 30.9800
RFQ
ECAD 1 0.00000000 Traco Power TEN 5WI (6W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module SCP TEN 5 75V Module download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2205 EAR99 8504.40.9580 10 6 W 2 200mA, 200mA 18V 82% 15V -15V - - 1.5 kV
TEN 6-11013WIRH Traco Power TEN 6-11013WIRH 39.7900
RFQ
ECAD 10 0.00000000 Traco Power TEN (6W) Tube Active -40°C ~ 90°C ITE (Commercial), Railway 1.25" L x 0.80" W x 0.42" H (31.8mm x 20.3mm x 10.7mm) Through Hole 24-DIP Module, 9 Leads Isolated Module Adjustable Output, Remote On/Off CB, cURus 160V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-TEN6-11013WIRH EAR99 8504.40.9580 10 5.94 W 1 - 400mA 36V 86% 15V - - - 3 kV 62368-1
TEN 5-4811WI Traco Power TEN 5-4811WI 29.3000
RFQ
ECAD 1 0.00000000 Traco Power TEN 5WI (6W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module SCP TEN 5 75V Module download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2655 EAR99 8504.40.9580 10 5 W 1 1A 18V 78% 5V - - - 1.5 kV
TEN 40-1223N Traco Power TEN 40-1223N 78.0200
RFQ
ECAD 10 0.00000000 Traco Power TEN 40N (40W) Tube Active -40°C ~ 80°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OVP, SCP, UVLO TEN 40 18V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 40 W 2 1.33A, 1.33A 9V 88% 15V -15V - - 1.5 kV
TEN 40-4823 Traco Power TEN 40-4823 97.1300
RFQ
ECAD 1856 0.00000000 Traco Power TEN 40 (40W) Tube Active -40°C ~ 75°C ITE (Commercial) 2.00" L x 2.00" W x 0.40" H (50.8mm x 50.8mm x 10.2mm) Through Hole 9-DIP Module, 8 Leads Isolated Module Remote On/Off, OCP, OTP, OVP, SCP, UVLO TEN 40 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 5 40 W 2 1.33A, 1.33A 36V 87% 15V -15V - - 1.5 kV
TMR 2-4810WIN Traco Power TMR 2-4810WIN 16.8800
RFQ
ECAD 10 0.00000000 Traco Power TMR 2WIN (2W) Tube Active -40°C ~ 90°C (With Derating) ITE (Commercial) 0.86" L x 0.37" W x 0.44" H (21.8mm x 9.3mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, OCP, SCP TMR 2 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 1.7 W 1 500mA 18V 74% 3.3V - - - 1.5 kV
TEC 2-4815 Traco Power TEC 2-4815 10.7900
RFQ
ECAD 26 0.00000000 Traco Power TEC 2 (2W) Tube Active -40°C ~ 95°C (With Derating) ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.1mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TEC 2 75V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1434 EAR99 8504.40.9580 10 2 W 1 83mA 36V 85% 24V - - - 1.6 kV
THN 20-2425WIR Traco Power THN 20-2425WIR 62.4800
RFQ
ECAD 7 0.00000000 Traco Power THN 20WIR (20W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial), Railway 1.00" L x 1.00" W x 0.39" H (25.4mm x 25.4mm x 9.9mm) Through Hole 6-DIP Module Isolated Module Adjustable Output, Remote On/Off THN 20 CB, cURus 36V - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 1951-THN20-2425WIR EAR99 8504.40.9580 10 20 W 2 - 417mA, 417mA 9V 91% 24V -24V - - 2.25 kV 50155; 62368-1
THD 10-1213N Traco Power THD 10-1213N 26.7460
RFQ
ECAD 9099 0.00000000 Traco Power THD 10N (10W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 9 Leads Isolated Module Remote On/Off, OCP, SCP THD 10 18V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 10 W 1 666mA 9V 89% 15V - - - 1.5 kV
TEN 25-1213 Traco Power TEN 25-1213 72.7700
RFQ
ECAD 6850 0.00000000 Traco Power TEN 25 (30W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 2.00" L x 1.60" W x 0.37" H (50.8mm x 40.6mm x 9.5mm) Through Hole 7-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP TEN 25 18V - download ROHS3 Compliant Not Applicable REACH Unaffected TEN25-1213 EAR99 8504.40.9580 5 30 W 1 2A 9V 88% 15V - - - 1.5 kV
TRV 1-1513M Traco Power TRV 1-1513M 16.4800
RFQ
ECAD 3 0.00000000 Traco Power TRV 1M (1W) Tube Active -40°C ~ 85°C ITE (Commercial), Medical 0.77" L x 0.39" W x 0.49" H (19.6mm x 9.9mm x 12.5mm) Through Hole 9-SIP Module, 4 Leads Isolated Module - TRV 1 CB, cURus 18V - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 1951-TRV1-1513M EAR99 8504.40.9580 5 1 W 1 - 67mA 12V 84% 15V - - - 5 kV
TEN 3-2410N Traco Power TEN 3-2410N 14.5900
RFQ
ECAD 395 0.00000000 Traco Power TEN 3N (3W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module SCP TEN 3 CB, cCSAus 36V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 2.5 W 1 750mA 18V 79% 3.3V - - - 1.5 kV
TEC 2-0913 Traco Power TEC 2-0913 10.7900
RFQ
ECAD 7417 0.00000000 Traco Power TEC 2 (2W) Tube Active -40°C ~ 95°C (With Derating) ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.1mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TEC 2 13.2V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1384 EAR99 8504.40.9580 10 2 W 1 134mA 4.5V 84% 15V - - - 1.6 kV
THN 20-2411 Traco Power THN 20-2411 46.2500
RFQ
ECAD 51 0.00000000 Traco Power THN 20 (20W) Tube Active -40°C ~ 75°C (With Derating) ITE (Commercial) 1.00" L x 1.00" W x 0.39" H (25.4mm x 25.4mm x 9.9mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OVP, SCP THN 20 36V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 20 W 1 4A 18V 90% 5V - - - 1.5 kV
TEM 3-1223N Traco Power TEM 3-1223N 14.2800
RFQ
ECAD 10 0.00000000 Traco Power TEM 3N (3W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 1.26" L x 0.79" W x 0.39" H (32.0mm x 20.0mm x 10.0mm) Through Hole 24-DIP Module, 12 Leads Isolated Module SCP TEM 3 13.2V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 3 W 2 100mA, 100mA 10.8V 82% 15V -15V - - 1.5 kV
TEN 60-4813WIN Traco Power TEN 60-4813WIN 120.3400
RFQ
ECAD 351 0.00000000 Traco Power TEN 60WIN (60W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OCP, OTP, OVP, SCP, UVLO TEN 60 75V Module download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 60 W 1 4A 18V 92% 15V - - - 1.5 kV
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2