Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Ratings | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | Termination Style | Voltage - Input (Max) | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Topology | Dimming | Voltage - Output | Current - Output (Max) | Voltage - Input (Min) | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Standard Number | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | SIC Programmable |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
NMP1K2-CKECCC-04 | 821.0300 | ![]() |
4193 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 5V | 48V | 12V | 5V | 5V | 5V | - | 4 kV | 60601-1; 62368-1 | 36 A | 5 A | 20 A | 36 A | 36 A | 36 A | ||||||||||
![]() |
NMP1K2-HEEEEC-04 | 821.0300 | ![]() |
9430 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 24V | 12V | 12V | 12V | 12V | 5V | - | 4 kV | 60601-1; 62368-1 | 10 A | 20 A | 20 A | 20 A | 20 A | 36 A | ||||||||||
![]() |
NMP1K2-CCC#E#-01 | 646.1400 | ![]() |
1058 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 780W | 3 | 88.5% | 5V | 5V | 12V | - | - | - | 4 kV | 60601-1; 62368-1 | 72 A | 36 A | 20 A | ||||||||||||||
![]() |
NMP1K2-ECC#EE-00 | 728.6700 | ![]() |
4925 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 5 | 88.5% | 12V | 5V | 5V | 12V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 36 A | 36 A | 20 A | 20 A | |||||||||||
![]() |
NMP1K2-KH#KHC-00 | 728.6700 | ![]() |
9424 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 48V | 24V | 48V | 24V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 5 A | 10 A | 5 A | 10 A | 36 A | |||||||||||
![]() |
NMP650-#KCC-00 | 473.5900 | ![]() |
7822 | 0.00000000 | MEAN WELL USA Inc. | NMP (650W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 3.50" W x 1.61" H (250.0mm x 89.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP650 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 600W | 3 | 88.5% | 48V | 5V | 5V | - | - | - | 4 kV | 60601-1; 62368-1 | 5 A | 36 A | 36 A | ||||||||||||||
![]() |
NMP1K2-CCHKCC-00 | 777.6200 | ![]() |
8569 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 5V | 5V | 24V | 48V | 5V | 5V | - | 4 kV | 60601-1; 62368-1 | 36 A | 36 A | 10 A | 5 A | 36 A | 36 A | ||||||||||
![]() |
NMP1K2-CCK#HK-00 | 728.6700 | ![]() |
6738 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 5 | 88.5% | 5V | 5V | 48V | 24V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 36 A | 36 A | 5 A | 10 A | 5 A | |||||||||||
![]() |
NMP1K2-H#EHCH-00 | 728.6700 | ![]() |
9406 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 24V | 12V | 24V | 5V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 20 A | 10 A | 36 A | 10 A | |||||||||||
![]() |
NMP1K2-#C#CEH-00 | 641.2200 | ![]() |
2330 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 840W | 4 | 88.5% | 5V | 5V | 12V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 36 A | 36 A | 20 A | 10 A | |||||||||||||
![]() |
NMP1K2-KHEKCK-00 | 816.1200 | ![]() |
5889 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 48V | 24V | 12V | 48V | 5V | 48V | - | 4 kV | 60601-1; 62368-1 | 5 A | 10 A | 20 A | 5 A | 36 A | 5 A | ||||||||||
![]() |
ENP-180-12 | 77.3300 | ![]() |
7748 | 0.00000000 | MEAN WELL USA Inc. | ENP-180 (180W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial) | 7.56" L x 7.01" W x 1.79" H (192.0mm x 178.0mm x 45.5mm) | Benchtop | Enclosed | Adjustable Output, PFC, Universal Input | ENP-180 | CB, CE, cULus | 90 ~ 264 VAC, 127 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9530 | 10 | 179W | 1 | 91% | 13.8V | - | - | - | - | No | 3 kV | 13 A | |||||||||||||||||
![]() |
NMP1K2-CKKKHC-07 | 823.3700 | ![]() |
9155 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 4 | 88.5% | 5V | 48V | 24V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 36 A | 15 A | 10 A | 36 A | |||||||||||||
![]() |
NMP1K2-EE#H#C-00 | 641.2200 | ![]() |
4096 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 900W | 4 | 88.5% | 12V | 12V | 24V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 10 A | 36 A | |||||||||||||
![]() |
EPS-120-15 | 24.3700 | ![]() |
5396 | 0.00000000 | MEAN WELL USA Inc. | EPS-120 (120W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial) | 4.00" L x 2.00" W x 1.14" H (101.6mm x 50.8mm x 29.0mm) | Chassis Mount | Open Frame | Adjustable Output, Universal Input | EPS-120 | CB, CE, cURus, TUV | 80 ~ 264 VAC, 113 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9520 | 72 | 84W (120W Forced Air) | 1 | 88.5% | 15V | - | - | - | - | - | 3 kV | 5.6 A | |||||||||||||||||
![]() |
NMP1K2-CCEK#E-01 | 698.9800 | ![]() |
1642 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 4 | 88.5% | 5V | 12V | 48V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 72 A | 20 A | 5 A | 20 A | |||||||||||||
![]() |
NMP1K2-CKHE#H-00 | 728.6700 | ![]() |
7435 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 5V | 48V | 24V | 12V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 36 A | 5 A | 10 A | 20 A | 10 A | |||||||||||
![]() |
NMP1K2-C#K#HE-00 | 610.9800 | ![]() |
9743 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 900W | 4 | 88.5% | 5V | 48V | 24V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 36 A | 5 A | 10 A | 20 A | |||||||||||||
![]() |
NMP1K2-EEEKKC-00 | 816.1200 | ![]() |
8281 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 12V | 12V | 12V | 48V | 48V | 5V | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 20 A | 5 A | 5 A | 36 A | ||||||||||
![]() |
NMP1K2-CCKCEK-01 | 821.0300 | ![]() |
6478 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 5V | 48V | 5V | 12V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 72 A | 5 A | 36 A | 20 A | 5 A | |||||||||||
![]() |
NMP1K2-CECCKH-03 | 821.0300 | ![]() |
2709 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 5V | 12V | 5V | 5V | 48V | 24V | - | 4 kV | 60601-1; 62368-1 | 36 A | 20 A | 36 A | 36 A | 5 A | 10 A | ||||||||||
![]() |
NMP1K2-#CCHKC-02 | 733.5900 | ![]() |
3210 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1020W | 4 | 88.5% | 5V | 24V | 48V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 72 A | 10 A | 5 A | 36 A | |||||||||||||
![]() |
NMP1K2-KK#HCC-01 | 733.5900 | ![]() |
4294 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 4 | 88.5% | 48V | 24V | 5V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 36 A | |||||||||||||
![]() |
NMP1K2-KCHCC#-04 | 733.5900 | ![]() |
5986 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1020W | 4 | 88.5% | 48V | 5V | 24V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 5 A | 36 A | 10 A | 72 A | |||||||||||||
![]() |
NMP1K2-C#ECCK-00 | 728.6700 | ![]() |
9433 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1020W | 5 | 88.5% | 5V | 12V | 5V | 5V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 36 A | 20 A | 36 A | 36 A | 5 A | |||||||||||
![]() |
NMP1K2-ECHHE#-03 | 733.5900 | ![]() |
1090 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 4 | 88.5% | 12V | 5V | 24V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 36 A | 20 A | 20 A | |||||||||||||
![]() |
NMP1K2-KKE#EH-00 | 728.6700 | ![]() |
3213 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 48V | 48V | 12V | 12V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 5 A | 5 A | 20 A | 20 A | 10 A | |||||||||||
![]() |
LPF-16-36 | 24.9500 | ![]() |
7586 | 0.00000000 | MEAN WELL USA Inc. | LPF-16 (16W) | Box | Active | -35°C ~ 70°C | IP30 | 5.83" L x 1.57" W x 1.26" H (148.0mm x 40.0mm x 32.0mm) | Chassis Mount | Constant Current, Voltage | OCP, OTP, OVP, SCP | LPF-16 | CB, CCC, CE, cURus, ENEC, PSE | Wire Leads | 305VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9510 | 40 | 16 W | 1 | AC DC Converter | - | 19.8 ~ 36V | 450mA | 90VAC | 86% | 3.75 kV | Not Verified | |||||||||||||||||
![]() |
HVG-480-24B | 182.6100 | ![]() |
6048 | 0.00000000 | MEAN WELL USA Inc. | HVG-480 (480W) | Box | Active | -40°C ~ 85°C | IP67 | 9.26" L x 4.92" W x 1.72" H (235.2mm x 125.0mm x 43.8mm) | Chassis Mount | Constant Current, Voltage | OCP, OTP, OVP, SCP | HVG-480 | cURus | Wire Leads | 528VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9530 | 4 | 480 W | 1 | AC DC Converter | Analog, PWM | 12 ~ 24V | 20A | 180VAC | 94% | 3.75 kV | Not Verified | |||||||||||||||||
![]() |
NMP1K2-#HHE##-02 | 558.7000 | ![]() |
3394 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 720W | 2 | 88.5% | 24V | 12V | - | - | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A |