SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-00AA0B-P-A-DK00000 Advanced Energy CX10S-00AA0B-P-A-DK00000 -
RFQ
ECAD 1617 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-00AA0B-P-A-DK00000 EAR99 8504.40.9540 1 390W 3 93% 5V 5V 12V - - - No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 15 A
CX10S-BG0AHG-P-A-DK00000 Advanced Energy CX10S-BG0AHG-P-A-DK00000 -
RFQ
ECAD 4770 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BG0AHG-P-A-DK00000 EAR99 8504.40.9540 1 625W 8 93% 12V 24V 24V 5V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 3 A 3 A 21 A 6 A 3 A
CX10S-CGHGD0-P-A-DK00000 Advanced Energy CX10S-CGHGD0-P-A-DK00000 -
RFQ
ECAD 4457 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CGHGD0-P-A-DK00000 EAR99 8504.40.9540 1 740W 8 93% 24V 24V 24V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A 6 A 3 A 3 A
CX10S-HDC0HH-P-A-DK00000 Advanced Energy CX10S-HDC0HH-P-A-DK00000 -
RFQ
ECAD 2935 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HDC0HH-P-A-DK00000 EAR99 8504.40.9540 1 700W 8 93% 5V 24V 48V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 4.17 A 8.3 A 6 A 3 A
CX10S-G0GCDA-P-A-DK00000 Advanced Energy CX10S-G0GCDA-P-A-DK00000 -
RFQ
ECAD 3208 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0GCDA-P-A-DK00000 EAR99 8504.40.9540 1 745W 7 93% 24V 24V 24V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 8.3 A 4.17 A
CX10S-GBABBA-P-A-DK00000 Advanced Energy CX10S-GBABBA-P-A-DK00000 -
RFQ
ECAD 4025 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GBABBA-P-A-DK00000 EAR99 8504.40.9540 1 870W 7 93% 24V 24V 12V 5V 12V 12V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 21 A 15 A 15 A
CX10S-AHACGC-P-A-DK00000 Advanced Energy CX10S-AHACGC-P-A-DK00000 -
RFQ
ECAD 4533 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AHACGC-P-A-DK00000 EAR99 8504.40.9540 1 830W 8 93% 5V 5V 24V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 6 A 3 A 21 A 8.3 A 3 A
CX10S-A0B00C-P-A-DK00000 Advanced Energy CX10S-A0B00C-P-A-DK00000 -
RFQ
ECAD 2751 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-A0B00C-P-A-DK00000 EAR99 8504.40.9540 1 485W 3 93% 5V 12V 24V - - - No 4 kV 60601-1; 60950-1; 62368-1 21 A 15 A 8.3 A
CX10S-DBDG0B-P-A-DK00000 Advanced Energy CX10S-DBDG0B-P-A-DK00000 -
RFQ
ECAD 7914 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DBDG0B-P-A-DK00000 EAR99 8504.40.9540 1 880W 6 93% 48V 12V 48V 24V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 15 A 4.17 A 3 A 3 A 15 A
CX10S-C0BAGC-P-A-DK00000 Advanced Energy CX10S-C0BAGC-P-A-DK00000 -
RFQ
ECAD 8126 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-C0BAGC-P-A-DK00000 EAR99 8504.40.9540 1 805W 6 93% 24V 12V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 15 A 21 A 3 A 3 A 8.3 A
CX10S-H0AA0G-P-A-DK00000 Advanced Energy CX10S-H0AA0G-P-A-DK00000 -
RFQ
ECAD 2214 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-H0AA0G-P-A-DK00000 EAR99 8504.40.9540 1 430W 6 93% 5V 24V 5V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 21 A 21 A 3 A 3 A
CX10S-H00HGA-P-A-DK00000 Advanced Energy CX10S-H00HGA-P-A-DK00000 -
RFQ
ECAD 4124 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-H00HGA-P-A-DK00000 EAR99 8504.40.9540 1 425W 7 93% 5V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 6 A 3 A 3 A 3 A
CX10S-0AA0DC-P-A-DK00000 Advanced Energy CX10S-0AA0DC-P-A-DK00000 -
RFQ
ECAD 7750 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0AA0DC-P-A-DK00000 EAR99 8504.40.9540 1 610W 4 93% 5V 5V 48V 24V - - No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 4.17 A 8.3 A
CX10S-CG0DDD-P-A-DK00000 Advanced Energy CX10S-CG0DDD-P-A-DK00000 -
RFQ
ECAD 3355 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CG0DDD-P-A-DK00000 EAR99 8504.40.9540 1 920W 6 93% 24V 24V 24V 48V 48V 48V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A 4.17 A 4.17 A 4.17 A
CX10S-BC0GHH-P-A-DK00000 Advanced Energy CX10S-BC0GHH-P-A-DK00000 -
RFQ
ECAD 6395 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BC0GHH-P-A-DK00000 EAR99 8504.40.9540 1 500W 8 93% 12V 24V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 8.3 A 3 A 3 A 6 A 3 A
CX10S-CDGCAA-P-A-DK00000 Advanced Energy CX10S-CDGCAA-P-A-DK00000 -
RFQ
ECAD 6824 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CDGCAA-P-A-DK00000 EAR99 8504.40.9540 1 930W 7 93% 24V 48V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 4.17 A 3 A 3 A 8.3 A 21 A
CX10S-AGDA0B-P-A-DK00000 Advanced Energy CX10S-AGDA0B-P-A-DK00000 -
RFQ
ECAD 3673 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AGDA0B-P-A-DK00000 EAR99 8504.40.9540 1 710W 6 93% 5V 24V 24V 48V 5V 12V No 4 kV 60601-1; 60950-1; 62368-1 21 A 3 A 3 A 4.17 A 21 A 15 A
CX10S-HHHDBB-P-A-DK00000 Advanced Energy CX10S-HHHDBB-P-A-DK00000 -
RFQ
ECAD 7245 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HHHDBB-P-A-DK00000 EAR99 8504.40.9540 1 860W 9 93% 5V 24V 5V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 6 A 3 A 6 A 3 A
CX10S-HGHCCH-P-A-DK00000 Advanced Energy CX10S-HGHCCH-P-A-DK00000 -
RFQ
ECAD 7978 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HGHCCH-P-A-DK00000 EAR99 8504.40.9540 1 820W 10 93% 5V 24V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 3 A 3 A 6 A 3 A
CX10S-0HGBBA-P-A-DK00000 Advanced Energy CX10S-0HGBBA-P-A-DK00000 -
RFQ
ECAD 9268 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0HGBBA-P-A-DK00000 EAR99 8504.40.9540 1 685W 7 93% 5V 24V 24V 24V 12V 12V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 3 A 3 A 15 A 15 A
CX10S-0GCGHG-P-A-DK00000 Advanced Energy CX10S-0GCGHG-P-A-DK00000 -
RFQ
ECAD 1259 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0GCGHG-P-A-DK00000 EAR99 8504.40.9540 1 660W 9 93% 24V 24V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 3 A 3 A 6 A
CX10S-G0HAHC-P-A-DK00000 Advanced Energy CX10S-G0HAHC-P-A-DK00000 -
RFQ
ECAD 6575 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0HAHC-P-A-DK00000 EAR99 8504.40.9540 1 625W 8 93% 24V 24V 5V 24V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 21 A 6 A
CX10S-HAAHHC-P-A-DK00000 Advanced Energy CX10S-HAAHHC-P-A-DK00000 -
RFQ
ECAD 2619 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HAAHHC-P-A-DK00000 EAR99 8504.40.9540 1 710W 9 93% 5V 24V 5V 5V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 21 A 21 A 6 A 3 A
CX10S-CCDBHH-P-A-DK00000 Advanced Energy CX10S-CCDBHH-P-A-DK00000 -
RFQ
ECAD 6994 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CCDBHH-P-A-DK00000 EAR99 8504.40.9540 1 980W 8 93% 24V 24V 48V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 8.3 A 4.17 A 15 A 6 A 3 A
CX10S-CAGCBB-P-A-DK00000 Advanced Energy CX10S-CAGCBB-P-A-DK00000 -
RFQ
ECAD 1121 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CAGCBB-P-A-DK00000 EAR99 8504.40.9540 1 985W 7 93% 24V 5V 24V 24V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 21 A 3 A 3 A 8.3 A 15 A
CX10S-G0HCBA-P-A-DK00000 Advanced Energy CX10S-G0HCBA-P-A-DK00000 -
RFQ
ECAD 6110 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0HCBA-P-A-DK00000 EAR99 8504.40.9540 1 705W 7 93% 24V 24V 5V 24V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 8.3 A 15 A
CX10S-DH0BGD-P-A-DK00000 Advanced Energy CX10S-DH0BGD-P-A-DK00000 -
RFQ
ECAD 9245 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DH0BGD-P-A-DK00000 EAR99 8504.40.9540 1 800W 7 93% 48V 5V 24V 12V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 6 A 3 A 15 A 3 A 3 A
CX10S-GD0G0C-P-A-DK00000 Advanced Energy CX10S-GD0G0C-P-A-DK00000 -
RFQ
ECAD 4549 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GD0G0C-P-A-DK00000 EAR99 8504.40.9540 1 640W 6 93% 24V 24V 48V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 3 A 3 A 8.3 A
CX10S-CBHGHC-P-A-DK00000 Advanced Energy CX10S-CBHGHC-P-A-DK00000 -
RFQ
ECAD 6488 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CBHGHC-P-A-DK00000 EAR99 8504.40.9540 1 900W 9 93% 24V 12V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 15 A 6 A 3 A 3 A 3 A
CX10S-0GBHGH-P-A-DK00000 Advanced Energy CX10S-0GBHGH-P-A-DK00000 -
RFQ
ECAD 6481 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0GBHGH-P-A-DK00000 EAR99 8504.40.9540 1 620W 9 93% 24V 24V 12V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 6 A 3 A 3 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse